General Information of This Antibody (ID: ANTI0IBKTF)
Antibody Name
YTH24.5
Organization
CL Great Ormond Street Institute of Child Health, Zayed Centre of Research, 20 Guilford Street, London WC1N 1DZ, UK; UCL Cancer Institute, 72 Huntley Street, London, UK.
Synonyms
YTH24.5
   Click to Show/Hide
Antibody Type
Monoclonal antibody (mAb)
Antibody Subtype
RAT IgG2b
Antigen Name
Undisclosed
 Antigen Info 
Click to Show/Hide the Sequence Information of This Antibody
Each Antibody-drug Conjugate Related to This Antibody
Full Information of The Activity Data of The ADC(s) Related to This Antibody
YTH24.5-SG3249 [Investigative]
Revealed Based on the Cell Line Data
Click To Hide/Show 3 Activity Data Related to This Level
Experiment 1 Reporting the Activity Date of This ADC [1]
Efficacy Data Half Maximal inhibitory Concentration (lC50)
0.03 pM
Positive CD45 expression (CD45+++/++)
Method Description
Cells at 0.5 × 105/mL were cultured for 5 days in mAb or ADC or medium (in triplicate wells) in wells of flat-bottom 96-well plates. PrestoBlue Cell Viability reagent (Thermo Fisher Scientific) was added and incubated for 1.5 h. Fluorescence intensity from each well was detected using a FLUOstar OPTIMA microplate reader (BMG Labtech, Aylesbury, UK) using excitation filter of 560-10 and emission filter of 590-10, and gain at 1,500. Data were plotted using GraphPad Prism software, and sigmoid dose-response non-linear regression was carried out to determine IC50 values.

   Click to Show/Hide
In Vitro Model Acute erythroid leukemia OCIM1 cells CVCL_2149
Experiment 2 Reporting the Activity Date of This ADC [1]
Efficacy Data Half Maximal inhibitory Concentration (lC50)
0.213 pM
Positive CD45 expression (CD45+++/++)
Method Description
Cells at 0.5 × 105/mL were cultured for 5 days in mAb or ADC or medium (in triplicate wells) in wells of flat-bottom 96-well plates. PrestoBlue Cell Viability reagent (Thermo Fisher Scientific) was added and incubated for 1.5 h. Fluorescence intensity from each well was detected using a FLUOstar OPTIMA microplate reader (BMG Labtech, Aylesbury, UK) using excitation filter of 560-10 and emission filter of 590-10, and gain at 1,500. Data were plotted using GraphPad Prism software, and sigmoid dose-response non-linear regression was carried out to determine IC50 values.

   Click to Show/Hide
In Vitro Model T acute lymphoblastic leukemia Jurkat cells CVCL_0065
Experiment 3 Reporting the Activity Date of This ADC [1]
Efficacy Data Half Maximal inhibitory Concentration (lC50) > 6000 pM Negative CD45 expression (CD45-)
Method Description
Cells at 0.5 × 105/mL were cultured for 5 days in mAb or ADC or medium (in triplicate wells) in wells of flat-bottom 96-well plates. PrestoBlue Cell Viability reagent (Thermo Fisher Scientific) was added and incubated for 1.5 h. Fluorescence intensity from each well was detected using a FLUOstar OPTIMA microplate reader (BMG Labtech, Aylesbury, UK) using excitation filter of 560-10 and emission filter of 590-10, and gain at 1,500. Data were plotted using GraphPad Prism software, and sigmoid dose-response non-linear regression was carried out to determine IC50 values.

   Click to Show/Hide
In Vitro Model Normal 293T cells CVCL_0063
YTH24.5-SG3376 [Investigative]
Revealed Based on the Cell Line Data
Click To Hide/Show 3 Activity Data Related to This Level
Experiment 1 Reporting the Activity Date of This ADC [1]
Efficacy Data Half Maximal inhibitory Concentration (lC50)
0.052 pM
Positive CD45 expression (CD45+++/++)
Method Description
Cells at 0.5 × 105/mL were cultured for 5 days in mAb or ADC or medium (in triplicate wells) in wells of flat-bottom 96-well plates. PrestoBlue Cell Viability reagent (Thermo Fisher Scientific) was added and incubated for 1.5 h. Fluorescence intensity from each well was detected using a FLUOstar OPTIMA microplate reader (BMG Labtech, Aylesbury, UK) using excitation filter of 560-10 and emission filter of 590-10, and gain at 1,500. Data were plotted using GraphPad Prism software, and sigmoid dose-response non-linear regression was carried out to determine IC50 values.

   Click to Show/Hide
In Vitro Model T acute lymphoblastic leukemia Jurkat cells CVCL_0065
Experiment 2 Reporting the Activity Date of This ADC [1]
Efficacy Data Half Maximal inhibitory Concentration (lC50)
0.096 pM
Positive CD45 expression (CD45+++/++)
Method Description
Cells at 0.5 × 105/mL were cultured for 5 days in mAb or ADC or medium (in triplicate wells) in wells of flat-bottom 96-well plates. PrestoBlue Cell Viability reagent (Thermo Fisher Scientific) was added and incubated for 1.5 h. Fluorescence intensity from each well was detected using a FLUOstar OPTIMA microplate reader (BMG Labtech, Aylesbury, UK) using excitation filter of 560-10 and emission filter of 590-10, and gain at 1,500. Data were plotted using GraphPad Prism software, and sigmoid dose-response non-linear regression was carried out to determine IC50 values.

   Click to Show/Hide
In Vitro Model Acute erythroid leukemia OCIM1 cells CVCL_2149
Experiment 3 Reporting the Activity Date of This ADC [1]
Efficacy Data Half Maximal inhibitory Concentration (lC50) > 6000 pM Negative CD45 expression (CD45-)
Method Description
Cells at 0.5 × 105/mL were cultured for 5 days in mAb or ADC or medium (in triplicate wells) in wells of flat-bottom 96-well plates. PrestoBlue Cell Viability reagent (Thermo Fisher Scientific) was added and incubated for 1.5 h. Fluorescence intensity from each well was detected using a FLUOstar OPTIMA microplate reader (BMG Labtech, Aylesbury, UK) using excitation filter of 560-10 and emission filter of 590-10, and gain at 1,500. Data were plotted using GraphPad Prism software, and sigmoid dose-response non-linear regression was carried out to determine IC50 values.

   Click to Show/Hide
In Vitro Model Normal 293T cells CVCL_0063
References
Ref 1 Anti-CD45 PBD-based antibody-drug conjugates are effective targeted conditioning agents for gene therapy and stem cell transplant