General Information of This Antibody
Antibody ID
ANI0SLWCT
Antibody Name
Cetuximab (LC) G7-CVIM
Antibody Type
Monoclonal antibody (mAb)
Antibody Subtype
Humanized IgG1-kappa Light chain
Antigen Name
Epidermal growth factor receptor (EGFR)
 Antigen Info 
Each Antibody-drug Conjugate Related to This Antibody
Full Information of The Activity Data of The ADC(s) Related to This Antibody
ADC14-0810 [Investigative]
Revealed Based on the Cell Line Data
Click To Hide/Show 3 Activity Data Related to This Level
Experiment 1 Reporting the Activity Date of This ADC [1]
Efficacy Data Half Maximal Inhibitory Concentration (IC50)
0.25 nM
Moderate EGFR expression (EGFR ++)
Method Description
Cells were plated at about 500 cells per well in a 96-well plate in 100 uL of media. The cells were incubated at 37°C in 5% CO2, for 24 hours. Then, serial dilutions of ADCs were added to the cells. The cells were incubated for 72 hours.
In Vitro Model Lung adenocarcinoma HCC827 cells CVCL_2063
Experiment 2 Reporting the Activity Date of This ADC [1]
Efficacy Data Half Maximal Inhibitory Concentration (IC50)
6.54 nM
High EGFR expression (CD19 +++)
Method Description
Cells were plated at about 500 cells per well in a 96-well plate in 100 uL of media. The cells were incubated at 37°C in 5% CO2, for 24 hours. Then, serial dilutions of ADCs were added to the cells. The cells were incubated for 72 hours.
In Vitro Model Skin squamous cell carcinoma A431 cells CVCL_0037
Experiment 3 Reporting the Activity Date of This ADC [1]
Efficacy Data Half Maximal Inhibitory Concentration (IC50) > 100 nM Low EGFR expression (EGFR +)
Method Description
Cells were plated at about 500 cells per well in a 96-well plate in 100 uL of media. The cells were incubated at 37°C in 5% CO2, for 24 hours. Then, serial dilutions of ADCs were added to the cells. The cells were incubated for 72 hours.
In Vitro Model Invasive breast carcinoma MCF-7 cells CVCL_0031
References
Ref 1 Compositions and methods related to anti-egfr antibody drug conjugates; 2017-03-30.

If you find any error in data or bug in web service, please kindly report it to Dr. Shen et al.