Antibody-drug Conjugate Information
General Information of This Antibody-drug Conjugate (ADC)
| ADC ID |
DRG0BOZLL
|
|||||
|---|---|---|---|---|---|---|
| ADC Name |
AU2017363246B2 Conjugate31A
|
|||||
| Synonyms |
Conjugate31A
Click to Show/Hide
|
|||||
| Organization |
MERSANA THERAPEUTICS, INC.
|
|||||
| Drug Status |
Investigative
|
|||||
| Drug-to-Antibody Ratio |
7.8
|
|||||
| Structure |
|
|||||
| Antibody Name |
Trastuzumab
|
Antibody Info | ||||
| Antigen Name |
Receptor tyrosine-protein kinase erbB-2 (ERBB2)
|
Antigen Info | ||||
| Payload Name |
AU2017363246B2+Conjugate31+Payload
|
Payload Info | ||||
| Linker Name |
AU2017363246B2+Conjugate31+Linker
|
Linker Info | ||||
| Conjugate Type |
Random conjugation through reduced inter-chain cysteines.
|
|||||
General Information of The Activity Data Related to This ADC
Revealed Based on the Cell Line Data
Full List of Activity Data of This Antibody-drug Conjugate
Revealed Based on the Cell Line Data
| Experiment 1 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) | < 100 nmol/L | High her2 expression (her2 +++) | ||
| Method Description |
BT474 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Invasive breast carcinoma | BT-474 cells | CVCL_0179 | ||
| Experiment 2 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) | < 100 nmol/L | High her2 expression (her2 +++) | ||
| Method Description |
SKBR3 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Breast adenocarcinoma | SK-BR-3 cells | CVCL_0033 | ||
| Experiment 3 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) | < 100 nmol/L | High her2 expression (her2 +++) | ||
| Method Description |
N87 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Gastric tubular adenocarcinoma | NCI-N87 cells | CVCL_1603 | ||
| Experiment 4 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) | < 100 nmol/L | Moderate her2 expression (her2++) | ||
| Method Description |
JIMT1 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Breast ductal carcinoma | JIMT-1 cells | CVCL_2077 | ||
| Experiment 5 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) | < 100 nmol/L | Low her2 expression (her2+) | ||
| Method Description |
MCF7 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Invasive breast carcinoma | MCF-7 cells | CVCL_0031 | ||
