Payload Information
General Information of This Payload
| Payload ID | PAY0OVOPO |
|||||
|---|---|---|---|---|---|---|
| Name | AU2017363246B2+Conjugate46+Payload |
|||||
| Synonyms |
AU2017363246B2+Conjugate46+Payload
Click to Show/Hide
|
|||||
Each Antibody-drug Conjugate Related to This Payload
Full Information of The Activity Data of The ADC(s) Related to This Payload
AU2017363246B2 Conjugate46A [Investigative]
Revealed Based on the Cell Line Data
| Experiment 1 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) |
0.02 nmol/L
|
High her2 expression (her2 +++) | ||
| Method Description |
SKBR3 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Breast adenocarcinoma | SK-BR-3 cells | CVCL_0033 | ||
| Experiment 2 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) |
0.07 nmol/L
|
High her2 expression (her2 +++) | ||
| Method Description |
N87 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Gastric tubular adenocarcinoma | NCI-N87 cells | CVCL_1603 | ||
| Experiment 3 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) |
0.1 nmol/L
|
High her2 expression (her2 +++) | ||
| Method Description |
BT474 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Invasive breast carcinoma | BT-474 cells | CVCL_0179 | ||
| Experiment 4 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) |
0.14 nmol/L
|
Low her2 expression (her2+) | ||
| Method Description |
MCF7 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Invasive breast carcinoma | MCF-7 cells | CVCL_0031 | ||
| Experiment 5 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) |
14.56 nmol/L
|
Moderate her2 expression (her2++) | ||
| Method Description |
JIMT1 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Breast ductal carcinoma | JIMT-1 cells | CVCL_2077 | ||
AU2017363246B2 Conjugate46B [Investigative]
Revealed Based on the Cell Line Data
| Experiment 1 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) |
0.03 nmol/L
|
High her2 expression (her2 +++) | ||
| Method Description |
SKBR3 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Breast adenocarcinoma | SK-BR-3 cells | CVCL_0033 | ||
| Experiment 2 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) |
0.11 nmol/L
|
High her2 expression (her2 +++) | ||
| Method Description |
BT474 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Invasive breast carcinoma | BT-474 cells | CVCL_0179 | ||
| Experiment 3 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) |
0.11 nmol/L
|
High her2 expression (her2 +++) | ||
| Method Description |
N87 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Gastric tubular adenocarcinoma | NCI-N87 cells | CVCL_1603 | ||
| Experiment 4 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) |
0.13 nmol/L
|
Low her2 expression (her2+) | ||
| Method Description |
MCF7 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Invasive breast carcinoma | MCF-7 cells | CVCL_0031 | ||
| Experiment 5 Reporting the Activity Date of This ADC | [1] | ||||
| Efficacy Data | Half Maximal inhibitory Concentration (lC50) |
100 nmol/L
|
Moderate her2 expression (her2++) | ||
| Method Description |
JIMT1 cell line was plated at 5,000cell/well in black walled 96-well plate and allowed to adhere overnight. CellTiter-Glo reagent was added to the wells at room temperature and the luminescent signal was measured
after 10 min using a SpectraMax M5 plate reader (Molecular Devices). Dose response curves were generated using SoftMax Pro software. IC50 values were determined from four-parameter curve fitting
Click to Show/Hide
|
||||
| In Vitro Model | Breast ductal carcinoma | JIMT-1 cells | CVCL_2077 | ||
